A new generation of advanced metering pump technology
Meet today’s demand for automated chemical delivery in industries

High turn down ratio

Full motor control varies the discharge and suction speeds independently to provide a full turndown ratio of 1000:1.

 

Energy savings and Eco-friendly

With the use of helical gears and spring assistance, power consumption is reduced by 70% compared to the standard spring back design.

 

Precise chemical dosing operation

The valve design maintains precise dosing at any flow rate whilst the motor regulates discharge and suction speeds to achieve high accuracy (+/-1%) all with a cost effective design from a mechanically driven diaphragm pump.

 

Efficient pump head design is incorporated with high compression

Fast priming without air locks is achieved with a high compression ratio due to a fixed (maximum) stroke length.

 

Constant injection with low impact

Flow control via discharge speed adjustment (with a fixed suction speed) assures constant injection at any flow rate. This system also reduces impact (inertia force) and load to the discharge line.

 

Viscous liquid transfer

Standard IX series is capable of pumping liquid viscosities of up to IX-B/C: 1000mPa•s, IX-D: 300mPa•s. Contact us for higher viscosity applications.

 

Safety design

Standard to all models is a diaphragm rupture detector, protecting users and the environment. Also, a detector for abnormal operation protects the pipework in case of an accidental high discharge pressure caused by clogging or improper operation. A drain hole also ensures safe operation even when the diaphragm is damaged.

 

IP65

Drive and control units are sealed separately to an IP65 enclosure.

 

Automatic control

The IX can run in analogue, pulse, batch or interval batch modes.

Specification

Specification of Pump (50/60Hz)

Capacity

0.0075 ~ 300 L/hr

Max. Pressure

1.7 MPa

Main Material

PVDF or SUS316

Liquid Temp. Range

PVDF: 0 ~ 50°C, SUS316: 0 ~ 80°C.

Max. Visocity

1000 mPa·s

 

Controller Specification

Operation Mode

MAN (Manual)

Use the UP and DOWN keys to set a flow rate

EXT

Analog fixed operation

4 ~ 20, 0 ~ 20, 20 - 4, 20 ~ 0 mA

Analog variable operation

Programmable 2-point setting (Input signal DC 0~20 mA, proportional to the discharge rate)

Pulse control

IX-B

0.000625 ~ 15.000000mL/PLS (IX-B007)
0.001250 ~ 30.000000L/PLS (IX-B015)
0.002500 ~ 60.000000mL/PLS (IX-B030)
0.003750 ~ 90.000000mL/PLS (IX-B045)

IX-C

0.00625 ~ 120mL/PLS (IX-C060)
0.01560 ~ 300mL/PLS (IX-C150)

IX-D

0.01560 ~ 300mL/PLS (IX-D150)
0.03120 ~ 600mL/PLS (IX-D300)

Batch control

IX-B

0.625mL/PLS ~ 15.000L/PLS (IX-B007)
1.250mL/PLS ~ 30.000L/PLS (IX-C150)
2.500mL/PLS ~ 60.000L/PLS (IX-B030)
3.750mL/PLS ~ 90.000L/PLS (IX-B045)

IX-C

6.25mL/PLS ~ 120L/PLS (IX-C060)
15.6mL/PLS ~ 300L/PLS (IX-C150)

IX-D

15.6mL/PLS ~ 300L/PLS (IX-D150)
31.2mL/PLS ~ 600L/PLS (IX-D300)

Interval batch control


Days: 0-9, Hours: 0~23, Minutes: 1~59

IX-B

0.625mL/PLS ~ 15.000L/PLS (IX-B007)
1.250mL/PLS ~ 30.000L/PLS (IX-B015)
2.500mL/PLS ~ 60.000L/PLS (IX-B030)
3.750mL/PLS ~ 90.000L/PLS (IX-B045)

IX-C

6.25mL/PLS ~ 120L/PLS (IX-C060)
15.6mL/PLS ~ 300L/PLS (IX-C150)

IX-D

15.6mL/PLS ~ 300L/PLS (IX-D150)
31.2mL/PLS ~ 600L/PLS (IX-D300)

Profibus control

Communication protocol: Profibus-DP-complaint international standard: EN50170 (IEC61158)

Input

STOP/ Pre-STOP

No-voltage contact or open collector

AUX

No-voltage contact or open collector

Interlock

No-voltage contact or open collector

Analog

DC 0~20 mA (Internal resistance: 200Ω)

Pulse

No-voltage contact or open collector, Max. pulse frequency 100 Hz。(Pulse signal input 5ms or above)

Output

Alarm1(OUT1)

No-voltage contact (mechanical relay): AC 250V, 3A (resistive load)
Each output item is selected by Enable/Disable.
Batch Complete/ STOP/Pre-STOP/Interlock/Leak Detection/Motor Overload/Drive Error

Alarm2 (OUT2)

No-voltage contact (mechanical relay): AC 250V, 3A (resistive load)
Each output item is selected by Enable/Disable.
Volume Prop. PLS/ Batch Complete/ STOP/Pre-STOP/Interlock/Leak Detection/Motor Overload/Drive Error

External power supply

DC 12V, 30mA or less

Current

DC 0~20A, Two-point setting (allowable load resistance: 300 Ω)

Power voltage

AC 100~240V 50/60Hz

Flowrate(L/min)
Max. Head(m)
Max. Discharge Pressure(MPa)
Min. Media Temp.(°C)
Max. Media Temp.(°C)
Water Controller Function