High turn down ratio
Full motor control varies the discharge and suction speeds independently to provide a full turndown ratio of 1000:1.
Energy savings and Eco-friendly
With the use of helical gears and spring assistance, power consumption is reduced by 70% compared to the standard spring back design.
Precise chemical dosing operation
The valve design maintains precise dosing at any flow rate whilst the motor regulates discharge and suction speeds to achieve high accuracy (+/-1%) all with a cost effective design from a mechanically driven diaphragm pump.
Efficient pump head design is incorporated with high compression
Fast priming without air locks is achieved with a high compression ratio due to a fixed (maximum) stroke length.
Constant injection with low impact
Flow control via discharge speed adjustment (with a fixed suction speed) assures constant injection at any flow rate. This system also reduces impact (inertia force) and load to the discharge line.
Viscous liquid transfer
Standard IX series is capable of pumping liquid viscosities of up to IX-B/C: 1000mPa•s, IX-D: 300mPa•s. Contact us for higher viscosity applications.
Safety design
Standard to all models is a diaphragm rupture detector, protecting users and the environment. Also, a detector for abnormal operation protects the pipework in case of an accidental high discharge pressure caused by clogging or improper operation. A drain hole also ensures safe operation even when the diaphragm is damaged.
IP65
Drive and control units are sealed separately to an IP65 enclosure.
Automatic control
The IX can run in analogue, pulse, batch or interval batch modes.
Specification
Specification of Pump (50/60Hz)
Capacity |
0.0075 ~ 300 L/hr |
Max. Pressure |
1.7 MPa |
Main Material |
PVDF or SUS316 |
Liquid Temp. Range |
PVDF: 0 ~ 50°C, SUS316: 0 ~ 80°C. |
Max. Visocity |
1000 mPa·s |
Controller Specification
Operation Mode |
MAN (Manual) |
Use the UP and DOWN keys to set a flow rate |
||
EXT |
Analog fixed operation |
4 ~ 20, 0 ~ 20, 20 - 4, 20 ~ 0 mA |
||
Analog variable operation |
Programmable 2-point setting (Input signal DC 0~20 mA, proportional to the discharge rate) |
|||
Pulse control |
IX-B |
0.000625 ~ 15.000000mL/PLS (IX-B007) |
||
IX-C |
0.00625 ~ 120mL/PLS (IX-C060) |
|||
IX-D |
0.01560 ~ 300mL/PLS (IX-D150) |
|||
Batch control |
IX-B |
0.625mL/PLS ~ 15.000L/PLS (IX-B007) |
||
IX-C |
6.25mL/PLS ~ 120L/PLS (IX-C060) |
|||
IX-D |
15.6mL/PLS ~ 300L/PLS (IX-D150) |
|||
Interval batch control |
Days: 0-9, Hours: 0~23, Minutes: 1~59 |
|||
IX-B |
0.625mL/PLS ~ 15.000L/PLS (IX-B007) |
|||
IX-C |
6.25mL/PLS ~ 120L/PLS (IX-C060) |
|||
IX-D |
15.6mL/PLS ~ 300L/PLS (IX-D150) |
|||
Profibus control |
Communication protocol: Profibus-DP-complaint international standard: EN50170 (IEC61158) |
|||
Input |
STOP/ Pre-STOP |
No-voltage contact or open collector |
||
AUX |
No-voltage contact or open collector |
|||
Interlock |
No-voltage contact or open collector |
|||
Analog |
DC 0~20 mA (Internal resistance: 200Ω) |
|||
Pulse |
No-voltage contact or open collector, Max. pulse frequency 100 Hz。(Pulse signal input 5ms or above) |
|||
Output |
Alarm1(OUT1) |
No-voltage contact (mechanical relay): AC 250V, 3A (resistive load) |
||
Alarm2 (OUT2) |
No-voltage contact (mechanical relay): AC 250V, 3A (resistive load) |
|||
External power supply |
DC 12V, 30mA or less |
|||
Current |
DC 0~20A, Two-point setting (allowable load resistance: 300 Ω) |
|||
Power voltage |
AC 100~240V 50/60Hz |